Control panels built to your drawings in UL 508A-listed partner shops

Outsourced UL 508A panel builds for OEMs

Custom control panels, built to your drawings

We take industrial control panel builds off the plates of equipment builders and plant owners. Panels are built to UL 508A in listed partner shops. Send us your schematics and BOM. We review them, quote the build, and every panel is tested before it ships.

Prefer to talk first? Call [PHONE TBD]

  • UL 508ABuilt in listed partner shops
  • Build to printYour drawings, your revision
  • Drawing reviewQuestions before we cut wire
  • TestedWiring check and power-up before ship
  • As-builtsDrawings that match the box

Capabilities

What we do

Build to print

You send the drawings and we build the panel to match them. If something on the print doesn't add up, we call you before we cut wire.

UL 508A panels

Panels are built and documented to UL 508A in listed partner shops. We check SCCR, wire sizing, and component spacing against the standard, so the label and nameplate hold up at inspection.

Drawing review

We go through your schematics, layout, and BOM before we quote. Typical catches: an undersized feeder, a component with no SCCR rating, or a part with a 20-week lead time.

Design help

No drawings yet? Send an I/O list and a sequence of operation. We can draw the panel for your review and approval before anything gets built.

Testing before ship

Every panel gets a point-to-point wiring check and a power-up test. If you send PLC code, we can load it and check the I/O before the panel goes on the truck.

More on what we do · Panel types we build

Partner shop credentials

Built in qualified partner shops

We manage your panel from drawings to delivery. The build itself happens in partner fab shops that hold the credentials below. These are our build partners' credentials, not Outsourced Controls' own. Ask which partner will build your panel and which of these apply to it.

  • UL 508AIndustrial control panels, built in UL 508A-listed partner shops
  • cULcUL labeling for Canadian sites, available through partner shops
  • CSACSA labeling available through partner shops
  • UL 698AHazardous-location panels (industrial control panels relating to hazardous locations) through qualified partners
  • UL 1203Explosion-proof and dust-ignition-proof enclosures through qualified partners
  • ISO 9001Partner shops run ISO 9001 quality management systems
  • LeanPartner shops run Lean production

Credentials vary by partner shop and by job. Standard and certification names belong to their owners; no logos are shown.

For OEMs

Your engineers should be designing machines, not chasing parts and wiring panels. Hand us the drawings. We handle layout, purchasing, wiring, and test. You get a panel that matches the print and is ready to mount.

Building the same panel over and over? Ask about pricing for repeat builds. How OEM builds work.

For plant owners

A UL 508A labeled panel is easier to get past an inspector. The label and the SCCR on the nameplate answer most of the questions before they get asked.

Each panel ships with as-built drawings, so your maintenance team isn't guessing three years from now.

Process

How it works

  1. Send your drawings

    Schematics, layout, and BOM. PDF, DWG, and DXF all work. A partial package is fine to start.

  2. We review and quote

    We mark up anything that looks wrong and send a quote with price and lead time.

  3. We build, test, and ship

    Approved drawings go to the floor. The panel is tested, labeled, and shipped with as-built drawings.

Markets

Industries we build for

  • Data center cooling and power
  • HVAC and custom AC equipment
  • Packaging and material handling machines
  • Water and wastewater
  • Food and beverage processing
  • Industrial equipment OEMs

Don't see your industry? If it runs on a control panel, send the drawings and we'll take a look. More on industries.

Work

Projects

We're adding project profiles. Each one will show the panel, the spec it was built to, and what the customer needed.

See all projects

New to UL 508A?

Our guidebook covers what the standard applies to, how SCCR is worked out, and what to have ready before an inspection.

Read the UL 508A guidebook

Questions we get a lot

What is UL 508A?

UL 508A is the UL standard for building industrial control panels. A shop listed under it can put the UL label on panels it builds and documents to the standard. Many inspectors and end customers ask for that label.

Outsourced Controls doesn't hold a UL 508A listing itself. Your panel is built in a UL 508A-listed partner shop, and that shop applies the label.

What do you need to quote a panel?

Schematics, a BOM, and a panel layout if you have one. Add the quantity, the date you need it, and any customer specs. If all you have is a sketch or an I/O list, send it anyway.

How long does a build take?

Parts usually set the schedule more than shop time does. Drives, PLCs, and some enclosures can take weeks to arrive. Your quote will list a lead time based on current part availability.

Will you use the brands on my BOM?

Yes. We build to the parts you specify. If a part is long-lead or obsolete, we suggest an alternate and wait for your OK before swapping anything.

Where do you ship?

Tell us where the panel is going and we will include freight in the quote.

Will you sign an NDA before we send drawings?

Yes. Send your NDA with the quote request, or ask for ours.

More questions and answers

Send us your drawings

Fill this out and attach what you have. We'll review it and get back to you with questions or a quote. Need to add shipping details or panel type? Use the full quote form.

We only use your drawings to quote your job.

Send us your drawings